| DTC Strategy |
- Lean to rich response rate check
|
- Leak in intake or exhaust system
- Faulty fuel system
- Front and rear HO2S connections reversed.
- Poor connection or damaged connector
- HO2S contamination
|
| Enable Conditions |
- Downstream O2 sensor operative readiness
- Mass air flow integral after leaving fuel cut-off is higher than 100g
- Downstream O2 sensor internal resistance is lower than 3KΩ
- Catalyst temperature model is higher than 400°C (752°F)
- Exhaust gas temperature model at sensor location is higher than 400°C (752°F)
- Mass air flow is between 10kg/h to 249kg/h
- Battery voltage is higher than 11V and lower than 16V
|
| Threshold Value |
- Signal gradient from 0.3V to 0.6V at entering fuel cut off out of range (Average of signal gradient is lower than 1500 mV/s)
|
| Diagnostic Time |
- 3 valid fuel cut-off phases.
|
| MIL ON Condition |
|