Module Inspection
| Inspection Item | Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |||
| Power inspection (HECU ↔ Chassis ground) |
|
HECU connector (with EPB) | 1, 30, 37 (power) | Chassis ground | - | B+ |
| Power inspection (HECU ↔ Chassis ground) |
|
HECU connector (W/O EPB) | 1, 25, 32 (power) | Chassis ground | - | B+ |
| Open in circuit inspection (HECU ↔ Chassis ground) |
|
HECU connector (with EPB) | 14, 46 (ground) | Chassis ground | - | Approx. below 1Ω |
| Open in circuit inspection (HECU ↔ Chassis ground) |
|
HECU connector (W/O EPB) | 13, 38 (ground) | Chassis ground | - | Approx. below 1Ω |
Good
- Go to "P-CAN INSPECTION " procedure.
No Good
- Repair as necessary and Go to "VERIFICATION OF REPAIR " procedure.