Generator Specifications

GENERATOR IDENTIFICATION

Application Specification
Polarity Negative Ground
Brush Length
New 0.78" (20 mm)
Worn, Minimum Free Protrusion From Brush Box 0.39" (10 mm)
Brush Spring Pressure Flush With Box Face 5-10 oz. (136-279 g)
Rectifier Pack Output Rectification 3 Positive Side & 3 Ground Side (6 Diodes)
Field Winding Supply Rectification 3 diodes
Stator Windings 3 Phase-Delta Connected
Field Winding Rotor Poles 12
Maximum Speed 16,000 RPM
Winding Resistance at 68°F (20°C) 2.6 ohms
Control Field Voltage Sensed Regulation
Regulator Type 15 TR
Regulator Voltage 13.6-14.4 volts
Nominal Output
Condition Hot
Generator Speed 6000 RPM
Control Voltage 14 Volt
Amp 80 amp