Generator Load Test
NOTE:
The following instructions refer to the use of suitable test equipment using a carbon pile rheostat.
NOTE:
Also see CHARGING CIRCUIT RESISTANCE TEST
.
- Connect test equipment referring to the manufacturer's instructions.
- Start engine and run at 3,000 RPM without accessory load.
- Rotate the carbon pile load control to achieve the greatest output (amps) without allowing voltage to fall below 12.0 volts. A reading of 80 amps, minus 10 percent to allow for EFI and ignition loss, should be obtained.
- Run engine at 3,000 RPM, switch selector to regulator test, read voltmeter. A reading of 13.6-14.4 volts should be obtained.
- Switch selector to diode/stator test, switch on headlamps to load alternator. Raise engine speed to 3,000 RPM, read voltmeter. The needle must be within the OK range.