Air Conditioning Compressor Replacement
A new compressor is supplied filled with a full charge (X cm3) of refrigerant oil. A calculated quantity of oil must be drained from the new compressor before fitting. To calculate the quantity of oil to be drained:
- Remove the drain plug from the old compressor.
- Invert the compressor and gravity drain the oil into a calibrated measuring cylinder. Rotate the compressor clutch to ensure the compressor is completely drained.
- Note the quantity of oil drained (Y cm3).
- Calculate the quantity of oil to be drained from the new compressor using the following formula:
- X cm3 - (Y cm3 + 20 cm3) = Q cm3
- Remove the drain plug from the new compressor and drain Q cm3 of oil. Fit and tighten the compressor drain plug.