LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Land Rover >> 2003 >> Range Rover >> Repair and Diagnosis >> General Information >> Specifications Index >> Common Specs & Procedures >> Air Conditioning >> Automatic System >> Service Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Specifications

SERVICE SPECIFICATIONS - HVAC

Application Specification
Compressor Type (1) Nippondenso 10PA17 10-Cyl.
System Oil Capacity (1) 3.8 ozs.
Oil Quantities Lost When Components Are Changed
Condenser/Receiver-Drier (1) 1.0 oz.
Evaporator (1) 0.7 oz.
Pipe/Hose (1) 0.3 oz.
Refrigerant (R-134a) Capacity 17.0-18.6 ozs.
Relief Valve Operating Pressure 497-600 psi (34.3-41.4 bar)
System Operating Pressures (2)
High Side 256-341 psi (18.0-24.0 kg/cm2 )
Low Side 27-37 psi (1.9-2.6 kg/cm2 )
(1) Use Nippondenso ND-OIL 8 refrigerant oil.
(2) With inlet air temperature 77-84°F (25-29°C), humidity greater than 80 percent and engine speed at 1500 RPM for 10 minutes with A/C operating.