Deployable Side Step Operation (LTB00432NAS2)
Publication date: 2012-03-29Reference number: LTB00432NAS2
DEPLOYABLE SIDE STEP OPERATION
TECHNICAL SERVICE BULLETIN
| LAND ROVER: | 2010 - Onwards Range Rover (LM) |
| SECTION: | 501 |
| AFFECTED VEHICLES: | Range Rover (LM) VIN: AA304426 - Onwards Model Year: 2010 - Onwards |
CONDITION SUMMARY
Situation: The Deployable Side Steps may deploy after the vehicle has been parked in an unlocked condition of five (5) minutes or longer. The side steps will then remain in the deployed position until a door is opened and closed. This may be due to a low battery voltage condition causing the Running Board Control Module software logic to interpret a 'Locking state unknown' message incorrectly and deploying the side steps.
Action: In the event of a customer concern of the above, refer to the REPAIR PROCEDURE outlined below to update the Running Board Control Module software.
PARTS
No parts necessary
TOOLS
IDS with latest IDS-DVD and Calibration File; first available on IDS-DVD129.01 Calibration File v100 Land Rover-approved Midtronics Vehicle Power Supply
WARRANTY
DDW requires the use of causal part numbers. Labor only claims must show the causal part number with a quantity of zero.
| DESCRIPTION | SRO | TIME (HOURS) | CONDITION CODE | CAUSAL PART |
|---|---|---|---|---|
| Update Running board control module software | 86.90.89/59 | 0.30 | 42 | VPLMP0097 |
Normal Warranty policies and procedures apply
REPAIR PROCEDURE
UPDATE THE RUNNING BOARD CONTROL MODULE SOFTWARE
- Connect the Land Rover-approved Midtronics Vehicle Power Supply to the vehicle battery.
- Turn ignition 'ON' (engine not running).NOTE: IDS must be loaded with IDS-DVD129.01 v100 or later.
- Connect the IDS to the vehicle and begin a new Symptom Driven Diagnostics (SDD) session.
- Follow the on-screen prompts, allowing SDD to read the VIN and identify the vehicle.
- From the Session Type selection screen, choose 'Diagnosis'.
- Select the 'Selected Symptoms' tab, and then select:
- Body > External accessories > Deployable running boards
- Select 'continue'.
- Select the 'Recommendations' tab.
- From the Recommendations tab, select 'Run' to 'Configure existing module - Running board control module'
- Follow all on-screen instructions to complete this task.
- Exit the current session.
- Disconnect the IDS and the Midtronics Vehicle Power Supply from the vehicle.