| Main interior lamp inoperative |
NOTE:
Operate the main interior lamp switch for 3 seconds to toggle automatic mode on/off
- Main interior lamp toggled off
- Bulb(s) failure
- Fuse(s) blown
- Main interior lamp circuit short circuit to ground, open circuit, high resistance
- Main interior lamp switch fault
|
- Check that the main interior lamp is not toggled off
- Check the bulb(s) condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the main interior lamp circuit for short circuit to ground, open circuit, high resistance
- Test the operation of the main interior lamp switch
|
| Waterfall lighting LED inoperative |
- LED failure
- Fuse(s) blown
- LED circuit short circuit to ground, open circuit, high resistance
|
- Check the LED condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the LED circuit for short circuit to ground, open circuit, high resistance
|
| Map reading lamp(s) inoperative |
- Bulb(s) failure
- Fuse(s) blown
- Vanity mirror lamp circuit short circuit to ground, open circuit, high resistance
- Map reading lamp switch fault
|
- Check the bulb(s) condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the map reading lamp circuit for short circuit to ground, open circuit, high resistance
- Test the operation of the map reading lamp switch
|
| Vanity mirror lamp(s) inoperative |
- Bulb failure
- Fuse(s) blown
- Vanity mirror lamp circuit short circuit to ground, open circuit, high resistance
- Vanity mirror lamp switch fault
|
- Check the bulb condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the vanity mirror lamp circuit for short circuit to ground, open circuit, high resistance
- Test the operation of the vanity mirror lamp switch
|
| Glove compartment lamp inoperative |
- Bulb failure
- Fuse(s) blown
- Glovebox lamp circuit short circuit to ground, open circuit, high resistance
- Glovebox lamp switch fault
|
- Check the bulb condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the glovebox lamp circuit for short circuit to ground, open circuit, high resistance
- Test the operation of the glovebox lamp switch
|
| Footwell lamp inoperative |
- Bulb failure
- Fuse(s) blown
- Footwell circuit short circuit to ground, open circuit, high resistance
|
- Check the bulb condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the puddle lamp circuit for short circuit to ground, open circuit, high resistance
|
| Door mirror approach lamp(s) inoperative |
- Bulb failure
- Fuse(s) blown
- Door mirror approach lamp circuit short circuit to ground, open circuit, high resistance
|
- Check the bulb condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the door mirror approach lamp circuit for short circuit to ground, open circuit, high resistance
|
| Puddle lamp(s) inoperative |
- Bulb failure
- Fuse(s) blown
- Puddle lamp circuit short circuit to ground, open circuit, high resistance
|
- Check the bulb condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the puddle lamp circuit for short circuit to ground, open circuit, high resistance
|
| Luggage compartment lamp inoperative |
- Bulb failure
- Fuse(s) blown
- Luggage compartment lamp circuit short circuit to ground, open circuit, high resistance
- Luggage compartment lamp switch fault
|
- Check the bulb condition
- Check the fuse(s)
- Refer to the electrical circuit diagrams and test the luggage compartment lamp circuit for short circuit to ground, open circuit, high resistance
- Test the operation of the luggage compartment lamp switch
|