DTC C2007-77: Right Motor - Commanded position not reachable: Action
- Refer to the electrical circuit diagrams and check the right electric park brake actuator circuit for short circuit to ground, short circuit to power, open circuit, high resistance. Repair the circuits as required
- Check the power line and every electrical connector between the right actuator and control unit for corrosion, tight fit, and correct polarity
- Check for other failures related to the right actuator (PBC) and the actuator control (HOST) and follow their service instructions
- Perform ignition change and delete failure memory (switch the Ignition OFF and back ON, then clear the Diagnostic Trouble Code(s))
- Check functionality by applying and releasing the electric park brake