DTC C2007-13: Right Motor - Circuit open: Action
- Refer to the electrical circuit diagrams and check the right electric park brake actuator circuit for open circuit, high resistance
- Check the power line and connectors between the right actuator and HW driver control
- Check the failure memory for host failures related to the control of the right actuator and follow the repair instructions
- Perform ignition change and delete failure memory (switch the Ignition OFF and back ON, then clear the Diagnostic Trouble Code(s))
- Check functionality by applying and releasing the electric park brake
- If the DTC is set again, perform ignition change and delete failure memory (switch the Ignition OFF and back ON, then clear the Diagnostic Trouble Code(s))
- Connect right actuator with the left side cable and vice versa and apply and release the electric park brake. If the failure C2008-13 is set: exchange (original) right actuator. If the failure C2007-13 is set: search for failures in the power line between host and right actuator and in the control of the right actuator (HOST)