LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2000 >> GS 300 L6-3.0L (2JZ-GE) >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Oxygen Sensor >> Testing and Inspection
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Oxygen Sensor: Testing and Inspection

INSPECTION

1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSORS (BANK 1, 2 SENSOR 1 AND BANK 1 SENSOR 2)
a. Disconnect the oxygen sensor connectors.




b. Using an ohmmeter, measure the resistance between the terminals +B and HT.

Resistance: 11 - 16 Ohms at 20 °C (68 °F)

If the resistance is not as specified, replace the sensor.

Torque: 45 Nm (450 kg.cm, 33 ft.lb)

c. Reconnect the oxygen sensor connectors.

2. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR (BANK 2 SENSOR 2)
a. Take out the front side of the floor carpet.




b. Disconnect the oxygen sensor connector.
Using an ohmmeter, measure the resistance between the terminals +B and HT.

Resistance: 11 - 16 Ohms at 20 °C (68 °F)

If the resistance is not as specified, replace the sensor.

Torque: 45 Nm (450 kg.cm, 33 ft.lb)

c. Reconnect the oxygen sensor connector.
d. Reinstall the floor carpet.

3. INSPECT OPERATION OF HEATED OXYGEN SENSOR