Customize Parameters
HINT:
The following items can be customized.
Meter ECU:
CUSTOMIZE PARAMETERS
| Display (Item) | Default | Contents | Setting |
|---|---|---|---|
| KEY REMND VOLUM | LARGE | Function that changes key reminder buzzer's volume | LARGE/MEDIUM/SMALL |
| KEY REMND SOUND | NORMAL | Function that changes key reminder buzzer's frequency | NORMAL/FAST/SLOW/0s |
NOTE:
- When the customer requests a change in a function, first make sure that the function(s) can be customized.
- Be sure to record the current settings before customizing.
- When troubleshooting a function, first make sure that the function is not set to OFF.