Inspection Procedure
- CHECK GENERATOR ASSEMBLY (TERMINAL B)
- Check the generator's tightening torque value.
Standard torque
TORQUE SPECIFICATIONGenerator Standard torque Terminal 1 (B) 12 N*m (122 kgf*cm, 8.82 ft.*lbf)
NG: TIGHTEN GENERATOR ASSEMBLY (TERMINAL B)
OK: Go to next step
- Check the generator's tightening torque value.
- CHECK GENERATOR ASSEMBLY (IG INPUT VOLTAGE)
- Disconnect the E24 generator connector.
- Measure the resistance according to the value(s) in the table below.
Standard voltage
STANDARD VOLTAGE SPECIFICATIONTester Connection Switch Condition Specified Condition E24-2 (IG) - Body ground Engine switch on (IG) 11 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE PASSENGER SIDE JUNCTION BLOCK (ELECTRIC POWER CONTROL ECU)