- CUSTOMIZING FUNCTION WITH INTELLIGENT TESTER OR TECHSTREAM (REFERENCE) NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Connect the intelligent tester or Techstream to the DLC3.
- Turn the power switch ON (IG)
- Turn the tester on.
- Enter the following menus
- Intelligent tester - Select. CUSTOMIZE
- Techstream - Select. Customize Setting
- Select the setting by referring to the table below
- Intelligent tester
AIR CONDITIONER
CUSTOMIZE PARAMETERS CHART - AIR CONDITIONERDisplay Default Contents Setting SET TEMP SHIFT NORMAL To control the shifted temperature against the display temperature +2 C / + 1 C / NORMAL / -1 C / -2 C AIR INLET MODE AUTO In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode MANUAL/AUTO COMPRESSOR MODE AUTO Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF MANUAL/AUTO COMPRS/DEF OPER LINK Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF NORMAL/LINK GAS SENS SHIFT NORMAL Function to change the sensitivity of the exhaust gas sensor MU MORE / MORE / LI MORE / NORMAL / LI LESS / LESS / MU LESS BUTTON PRS BUZ ON Function to sound a buzzer when button is pressed OFF/ON FOOT/DEF MODE ON Function to turn the airflow from FOOT / DEF ON automatically when AUTO MODE is ON OFF/ON AUTO BLOW UP ON Function to change the blower level automatically when the defroster is ON OFF/ON FILTER SENS NORMAL Function to change the sensitivity of the air conditioning filter clogging sensor LESS/NORMAL / MORE AMBIENT TMP SFT NORMAL Function to control the shifted ambient temperature in relation to the displayed ambient temperature +3 C / +2 C / +1 C/NORMAL/-1 C / -2 C / -3 C - Techstream
Air Conditioner
CUSTOMIZE PARAMETERS CHART - AIR CONDITIONERDisplay Default Contents Setting Set Temperature Shift Normal To control the shifted temperature against the display temperature +2 C / +1 C / Normal / -1 C / -2 C Air Inlet Mode Automatic In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode Manual / Automatic Compressor Mode Automatic Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF Manual/Automatic Compressor/Air Inlet DEF operation Link Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF Normal / Link Emission Gas Sensor Shift Normal Function to change the sensitivity of the exhaust gas sensor Much More / More / Little More / Normal / Little Less / Less / Much Less Button Press Buzzer ON Function to sound a buzzer when button is pressed OFF / ON Foot/DEF Auto Mode ON Function to turn the airflow from FOOT / DEF ON automatically when AUTO MODE is ON OFF / ON Foot/DEF Automatic Blow Up Function ON Function to change the blower level automatically when the defroster is ON OFF / ON Filter Sensor Normal Function to change the sensitivity of the air conditioning filter clogging sensor Less / Normal / More Ambient Temperature Shift Normal Function to control the shifted ambient temperature in relation to the displayed ambient temperature +3 C / +2 C / +1 C / Normal / -1 C / - 2 C / -3 C
- Intelligent tester