Monitor Strategy
| Related DTCs | P0116: ECT sensor rationality (cold start monitor) P0116: ECT sensor rationality (soak monitor) |
| Required Sensors/Components (Main) | ECT sensor |
| Required Sensors/Components (Sub) | Intake Air Temperature (IAT) sensor and Mass Air Flow (MAF) meter |
| Frequency of Operation | Once per driving cycle |
| Duration | 10 seconds |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |