Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch: Procedure
- READ VALUE USING TECHSTREAM (D DOOR P/W AUTO SW)
- Use the Data List to check if the multiplex network master switch is functioning properly. Refer to DATA LIST / ACTIVE TEST [03/2012 - ]
.MASTER SWITCH
Tester Display Measurement Item/Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver side power window auto up/down signal / ON or OFF ON: Front power window switch LH auto up/down on multiplex network master switch operated
OFF: Front power window switch LH on multiplex network master switch not operated- OK
On Techstream screen, item changes between ON and OFF according to above chart.
NG → See step 5
OK: Go to next step
- Use the Data List to check if the multiplex network master switch is functioning properly. Refer to DATA LIST / ACTIVE TEST [03/2012 - ]
.
- READ VALUE USING TECHSTREAM (D DOOR P/W AUTO SW)
- Use the Data List to check if the multiplex network master switch is functioning properly. Refer to DATA LIST / ACTIVE TEST [03/2012 - ]
.D-DOOR MOTOR
Tester Display Measurement Item/Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver side power window auto up/down signal / ON or OFF ON: Front power window switch LH auto up/down operated
OFF: Front power window switch LH not operated- OK
On Techstream screen, item changes between ON and OFF according to above chart.
NG → See step 4
OK: Go to next step
- Use the Data List to check if the multiplex network master switch is functioning properly. Refer to DATA LIST / ACTIVE TEST [03/2012 - ]
.
- PERFORM INITIALIZATION
- Initialize the front power window regulator motor assembly LH. Refer to INITIALIZATION [03/2012 - ] .
- Check that the front door power window LH moves when the auto up and down functions of the multiplex network master switch assembly are operated. Refer to OPERATION CHECK [03/2012 - ]
.
OK
Driver side auto up and down functions are normal.
NG → See step 6
OK → END (POWER WINDOW CONTROL SYSTEM HAS NOT BEEN INITIALIZED)
- CHECK MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
- Temporarily replace the multiplex network master switch assembly with a new or normally functioning one. Refer to REMOVAL [03/2012 - ] .
- Check that the front door power window LH moves when the auto up and down functions of the multiplex network master switch assembly are operated. Refer to OPERATION CHECK [03/2012 - ]
.
OK
Driver side auto up and down functions are normal.
NG → See step 6
OK → END (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY WAS DEFECTIVE)
- REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY. Refer to REMOVAL [03/2012 - ]
- REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [03/2012 - ]