Typical Malfunction Thresholds
CASE 1
| Following conditions is met | 2 data |
| One of the following conditions is met (3 time) | (a), (b) or (c) |
| (a) EEPROM communication timeout | Occurred |
| (b) Permanent Fault Code | Not stored |
| (c) Permanent Fault Code | Not equal to commanded Fault Code |
CASE 2
| Following conditions is met | 2 data |
| Either of the following conditions is met (3 time) | (a) or (b) |
| (a) EEPROM communication timeout | Occurred |
| (b) Permanent Fault Code | Stored |
CASE 3
| Following conditions is met | 2 data |
| Either of the following conditions is met | (a) or (b) |
| (a) EEPROM communication timeout (3 time) | Occurred |
| (b) Permanent Fault Code data (10 time) | Mismatch |