Component Testing Procedure
MULTIFUNCTION SWITCH, LAMP PORTION COMPONENT TESTING
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| High Beam/Flash-to-Pass | 9 and 8 | High beams | 60ohm |
| Neutral | Open circuit | ||
| Flash-to-pass | 15ohm | ||
| Hazard | 7 and 8 | Turn signal switch in neutral, Hazard On | Closed circuit |
| Turn signal switch in neutral, Hazard Off | Open circuit | ||
| Turn signals | 7 and 8 | Left turn | 182ohm |
| Neutral | Open circuit | ||
| Right turn | 60ohm |