Component testing procedure
THIRD ROW FOLDING SEAT SWITCH, LEFT - COMPONENT TESTING
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Up/Down Circuit | 2 and 5 | Up | Open circuit |
| Rest | Closed circuit | ||
| Down | |||
| 5 and 6 | Up | Open circuit | |
| Rest | Closed circuit | ||
| Down | |||
| 1 and 2 | Up | Closed circuit | |
| Rest | |||
| Down | Open circuit | ||
| 1 and 6 | Up | Closed circuit | |
| Rest | |||
| Down | Open circuit |