| ACCM |
B11EE:19 |
A/C Compressor: Circuit Current Above Threshold |
GO to Pinpoint Test AL |
| ACCM |
B11EE:41 |
A/C Compressor: General Checksum Failure |
GO to Pinpoint Test AU |
| ACCM |
B11EE:4B |
A/C Compressor: Over Temperature |
GO to Pinpoint Test AL |
| ACCM |
B11EE:92 |
A/C Compressor: Performance or Incorrect Operation |
GO to Pinpoint Test AL |
| ACCM |
P0562:00 |
System Voltage Low: No Sub Type Information |
GO to Pinpoint Test AL |
| ACCM |
P0563:00 |
System Voltage High: No Sub Type Information |
GO to Pinpoint Test AL |
| ACCM |
P0AFA:16 |
Hybrid/EV Battery System Voltage Low: Circuit Voltage Below Threshold |
GO to Pinpoint Test AL |
| ACCM |
P0AFB:17 |
Hybrid/EV Battery System Voltage High: Circuit Voltage Above Threshold |
GO to Pinpoint Test AL |
| ACCM |
P0AFB:1C |
Hybrid/EV Battery System Voltage High: Circuit Voltage Out Of Range |
GO to Pinpoint Test AL |
| ACCM |
U0001:88 |
High Speed CAN Communication Bus: Bus Off |
GO to Pinpoint Test AR |
| ACCM |
U0100:00 |
Lost Communication With ECM/PCM 'A': No Sub Type Information |
GO to Pinpoint Test AN |
| ACCM |
U0111:00 |
Lost Communication With Battery Energy Control Module 'A': No Sub Type Information |
GO to Pinpoint Test AO |
| ACCM |
U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test P |
| ACCM |
U3000:04 |
Control Module: System Internal Failure |
GO to Pinpoint Test AU |
| ACCM |
U3000:42 |
Control Module: General Memory Failure |
GO to Pinpoint Test AU |
| ACCM |
U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test AU |
| BCMC |
B3A01:00 |
A/C Refrigerant Distribution Valve Actuator 'C' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test AX |
| BCMC |
B3A02:00 |
A/C Refrigerant Distribution Valve Actuator 'C' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test AX |
| BCMC |
B3A03:00 |
A/C Refrigerant Distribution Valve Actuator 'C' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test AX |
| BCMC |
P2611:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test AV |
| BCMC |
P2612:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test AV |
| BCMC |
P2613:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test AV |
| BCMC |
P2CFC:00 |
A/C Clutch Control Circuit: No Sub Type Information |
GO to Pinpoint Test C |
| BCMC |
P2CFD:00 |
A/C Clutch Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test C |
| BCMC |
P2CFE:00 |
A/C Clutch Control Circuit High: No Sub Type Information |
GO to Pinpoint Test C |
| BCMC |
P2E62:00 |
Engine Coolant Bypass Valve 'E' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test AW |
| BCMC |
P2E63:00 |
Engine Coolant Bypass Valve 'E' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test AW |
| BCMC |
P2E64:00 |
Engine Coolant Bypass Valve 'E' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test AW |
| HVAC |
B102E:11 |
Air Quality Sensor: Circuit Short To Ground |
GO to Pinpoint Test Y |
| HVAC |
B102E:15 |
Air Quality Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test Y |
| HVAC |
B102E:92 |
Air Quality Sensor: Performance or Incorrect Operation |
GO to Pinpoint Test Y |
| HVAC |
B1081:07 |
Left Temperature Damper Motor: Mechanical Failures |
GO to Pinpoint Test G |
| HVAC |
B1081:11 |
Left Temperature Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test G |
| HVAC |
B1081:12 |
Left Temperature Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test G |
| HVAC |
B1081:13 |
Left Temperature Damper Motor: Circuit Open |
GO to Pinpoint Test G |
| HVAC |
B1082:07 |
Right Temperature Damper Motor: Mechanical Failures |
GO to Pinpoint Test H |
| HVAC |
B1082:11 |
Right Temperature Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test H |
| HVAC |
B1082:12 |
Right Temperature Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test H |
| HVAC |
B1082:13 |
Right Temperature Damper Motor: Circuit Open |
GO to Pinpoint Test H |
| HVAC |
B1083:07 |
Recirculation Damper Motor: Mechanical Failures |
GO to Pinpoint Test I |
| HVAC |
B1083:11 |
Recirculation Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test I |
| HVAC |
B1083:12 |
Recirculation Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test I |
| HVAC |
B1083:13 |
Recirculation Damper Motor: Circuit Open |
GO to Pinpoint Test I |
| HVAC |
B1086:07 |
Air Distribution Damper Motor: Mechanical Failures |
GO to Pinpoint Test J |
| HVAC |
B1086:11 |
Air Distribution Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test J |
| HVAC |
B1086:12 |
Air Distribution Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test J |
| HVAC |
B1086:13 |
Air Distribution Damper Motor: Circuit Open |
GO to Pinpoint Test J |
| HVAC |
B10AF:11 |
Blower Fan Relay: Circuit Short To Ground |
GO to Pinpoint Test N |
| HVAC |
B10AF:15 |
Blower Fan Relay: Circuit Short To Battery Or Open |
GO to Pinpoint Test N |
| HVAC |
B10AF:15 |
Blower Fan Relay: Circuit Short To Battery Or Open |
GO to Pinpoint Test O |
| HVAC |
B10B3:11 |
Right Panel Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test AA |
| HVAC |
B10B3:15 |
Right Panel Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test AA |
| HVAC |
B10B4:11 |
Right Floor Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test AA |
| HVAC |
B10B4:15 |
Right Floor Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test AA |
| HVAC |
B10B5:11 |
Left Panel Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test AA |
| HVAC |
B10B5:15 |
Left Panel Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test AA |
| HVAC |
B10B6:11 |
Left Floor Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test AA |
| HVAC |
B10B6:15 |
Left Floor Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test AA |
| HVAC |
B10B7:11 |
Rear Air Discharge Temperature: Circuit Short To Ground |
GO to Pinpoint Test AG |
| HVAC |
B10B7:15 |
Rear Air Discharge Temperature: Circuit Short To Battery Or Open |
GO to Pinpoint Test AG |
| HVAC |
B10B9:12 |
Blower Control: Circuit Short To Battery |
GO to Pinpoint Test N |
| HVAC |
B10B9:14 |
Blower Control: Circuit Short To Ground Or Open |
GO to Pinpoint Test N |
| HVAC |
B10BA:12 |
Rear Blower Control: Circuit Short To Battery |
GO to Pinpoint Test AZ |
| HVAC |
B10BA:14 |
Rear Blower Control: Circuit Short To Ground Or Open |
GO to Pinpoint Test AZ |
| HVAC |
B11E3:07 |
Rear HVAC Damper Motor: Mechanical Failures |
GO to Pinpoint Test AG |
| HVAC |
B11E3:11 |
Rear HVAC Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test AG |
| HVAC |
B11E3:12 |
Rear HVAC Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test AG |
| HVAC |
B11E3:13 |
Rear HVAC Damper Motor: Circuit Open |
GO to Pinpoint Test AG |
| HVAC |
B11E4:07 |
Rear Air Distribution Damper Motor: Mechanical Failures |
GO to Pinpoint Test AI |
| HVAC |
B11E4:11 |
Rear Air Distribution Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test AI |
| HVAC |
B11E4:12 |
Rear Air Distribution Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test AI |
| HVAC |
B11E4:13 |
Rear Air Distribution Damper Motor: Circuit Open |
GO to Pinpoint Test AI |
| HVAC |
B11E5:11 |
Left HVAC Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test G |
| HVAC |
B11E5:15 |
Left HVAC Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test G |
| HVAC |
B11E6:11 |
Right HVAC Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test H |
| HVAC |
B11E6:15 |
Right HVAC Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test H |
| HVAC |
B11E7:11 |
Air Distribution Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test J |
| HVAC |
B11E7:15 |
Air Distribution Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test J |
| HVAC |
B11EC:12 |
Rear HVAC Blower Control Input: Circuit Short To Battery |
GO to Pinpoint Test AD |
| HVAC |
B11EC:14 |
Rear HVAC Blower Control Input: Circuit Short To Ground Or Open |
GO to Pinpoint Test AD |
| HVAC |
B11F0:11 |
Air Intake Damper Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test I |
| HVAC |
B11F0:15 |
Air Intake Damper Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test I |
| HVAC |
B1364:07 |
Left Rear Temperature Damper Motor: Mechanical Failures |
GO to Pinpoint Test AJ |
| HVAC |
B1364:11 |
Left Rear Temperature Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test AJ |
| HVAC |
B1364:12 |
Left Rear Temperature Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test AJ |
| HVAC |
B1364:13 |
Left Rear Temperature Damper Motor: Circuit Open |
GO to Pinpoint Test AJ |
| HVAC |
B1379:11 |
Rear Cabin Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test BD |
| HVAC |
B1379:15 |
Rear Cabin Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test BD |
| HVAC |
B14D3:11 |
Left Rear Panel Discharge Sensor: Circuit Short To Ground |
GO to Pinpoint Test BC |
| HVAC |
B14D3:15 |
Left Rear Panel Discharge Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test BC |
| HVAC |
B14D4:11 |
Left Rear Floor Discharge Sensor: Circuit Short To Ground |
GO to Pinpoint Test BC |
| HVAC |
B14D4:15 |
Left Rear Floor Discharge Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test BC |
| HVAC |
B1580:11 |
Console Airflow Shut Off Door Position Sensor: Circuit Short To Ground |
GO to Pinpoint Test BB |
| HVAC |
B1580:15 |
Console Airflow Shut Off Door Position Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test BB |
| HVAC |
B1581:07 |
Console Airflow Shut Off Door Damper Motor: Mechanical Failures |
GO to Pinpoint Test BB |
| HVAC |
B1581:11 |
Console Airflow Shut Off Door Damper Motor: Circuit Short To Ground |
GO to Pinpoint Test BB |
| HVAC |
B1581:12 |
Console Airflow Shut Off Door Damper Motor: Circuit Short To Battery |
GO to Pinpoint Test BB |
| HVAC |
B1581:13 |
Console Airflow Shut Off Door Damper Motor: Circuit Open |
GO to Pinpoint Test BB |
| HVAC |
B1582:11 |
Left Panel Discharge Sensor #3: Circuit Short To Ground |
GO to Pinpoint Test BC |
| HVAC |
B1582:15 |
Left Panel Discharge Sensor #3: Circuit Short To Battery Or Open |
GO to Pinpoint Test BC |
| HVAC |
B158C:11 |
Air Distribution Damper Position Sensor #3: Circuit Short To Ground |
GO to Pinpoint Test AF |
| HVAC |
B158C:15 |
Air Distribution Damper Position Sensor #3: Circuit Short To Battery Or Open |
GO to Pinpoint Test AF |
| HVAC |
B158F:11 |
Left HVAC Damper Position Sensor #3: Circuit Short To Ground |
GO to Pinpoint Test AJ |
| HVAC |
B158F:15 |
Left HVAC Damper Position Sensor #3: Circuit Short To Battery Or Open |
GO to Pinpoint Test AJ |
| HVAC |
B159B:11 |
Cabin Temperature Sensor #3: Circuit Short To Ground |
GO to Pinpoint Test BD |
| HVAC |
B159B:15 |
Cabin Temperature Sensor #3: Circuit Short To Battery Or Open |
GO to Pinpoint Test BD |
| HVAC |
B159E:07 |
Air Distribution Damper Motor #3: Mechanical Failures |
GO to Pinpoint Test AF |
| HVAC |
B159E:11 |
Air Distribution Damper Motor #3: Circuit Short To Ground |
GO to Pinpoint Test AF |
| HVAC |
B159E:12 |
Air Distribution Damper Motor #3: Circuit Short To Battery |
GO to Pinpoint Test AF |
| HVAC |
B159E:13 |
Air Distribution Damper Motor #3: Circuit Open |
GO to Pinpoint Test AF |
| HVAC |
B1A61:11 |
Cabin Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test E |
| HVAC |
B1A61:15 |
Cabin Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test E |
| HVAC |
B1A63:11 |
Right Solar Sensor: Circuit Short To Ground |
GO to Pinpoint Test Z |
| HVAC |
B1A63:15 |
Right Solar Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test Z |
| HVAC |
B1A64:11 |
Left Solar Sensor: Circuit Short To Ground |
GO to Pinpoint Test Z |
| HVAC |
B1A64:15 |
Left Solar Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test Z |
| HVAC |
B1A69:11 |
Humidity Sensor: Circuit Short To Ground |
GO to Pinpoint Test E |
| HVAC |
B1A69:15 |
Humidity Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test E |
| HVAC |
B1B71:11 |
Evaporator Temperature Sensor: Circuit Short To Ground |
GO to Pinpoint Test F |
| HVAC |
B1B71:15 |
Evaporator Temperature Sensor: Circuit Short To Battery Or Open |
GO to Pinpoint Test F |
| HVAC |
B1B7D:11 |
Rear Air Distribution Actuator: Circuit Short To Ground |
GO to Pinpoint Test AI |
| HVAC |
B1B7D:15 |
Rear Air Distribution Actuator: Circuit Short To Battery Or Open |
GO to Pinpoint Test AI |
| HVAC |
C1B14:11 |
Sensor Supply Voltage A: Circuit Short To Ground |
GO to Pinpoint Test AC |
| HVAC |
C1B14:12 |
Sensor Supply Voltage A: Circuit Short To Battery |
GO to Pinpoint Test AC |
| HVAC |
P24AE:09 |
Particulate Matter Sensor Circuit: Component Failures |
GO to Pinpoint Test AY |
| HVAC |
P24AE:8F |
Particulate Matter Sensor Circuit: Erratic |
GO to Pinpoint Test AY |
| HVAC |
P24AE:92 |
Particulate Matter Sensor Circuit: Performance or Incorrect Operation |
GO to Pinpoint Test AY |
| HVAC |
U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test P |
| HVAC |
U0155:00 |
Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information |
GO to Pinpoint Test Q |
| HVAC |
U0165:00 |
Lost Communication With HVAC Control Module - Rear: No Sub Type Information |
GO to Pinpoint Test S |
| HVAC |
U0249:00 |
Lost Communication With Entertainment Control Module -Rear 'B': No Sub Type Information |
GO to Pinpoint Test T |
| HVAC |
U0253:00 |
Lost Communication With Accessory Protocol Interface Module: No Sub Type Information |
GO to Pinpoint Test V |
| HVAC |
U025D:00 |
Lost Communication With Front Controls Interface Module 'B': No Sub Type Information |
GO to Pinpoint Test W |
| HVAC |
U0401:00 |
Invalid Data Received from ECM/PCM A: No Sub Type Information |
GO to Pinpoint Test AS |
| HVAC |
U0401:82 |
Invalid Data Received from ECM/PCM A: Alive / Sequence Counter Incorrect / Not Updated |
GO to Pinpoint Test AS |
| HVAC |
U0422:68 |
Invalid Data Received From Body Control Module: Event Information |
GO to Pinpoint Test AS |
| HVAC |
U0422:81 |
Invalid Data Received From Body Control Module: Invalid Serial Data Received |
GO to Pinpoint Test AS |
| HVAC |
U0452:00 |
Invalid Data Received From Restraints Control Module: No Sub Type Information |
GO to Pinpoint Test AS |
| HVAC |
U054A:68 |
Invalid Data Received From Entertainment Control Module-Rear 'B': Event Information |
GO to Pinpoint Test AS |
| HVAC |
U055E:68 |
Invalid Data Received From Front Controls Interface Module 'B': Event Information |
GO to Pinpoint Test AS |
| HVAC |
U1000:00 |
Solid State Driver Protection Active -Driver Disabled: No Sub Type Information |
GO to Pinpoint Test X |
| HVAC |
U2024:51 |
Control Module Cal-Config Data: Not Programmed |
GO to Pinpoint Test AT |
| HVAC |
U2100:00 |
Initial Configuration Not Complete: No Sub Type Information |
GO to Pinpoint Test AT |
| HVAC |
U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test AU |
| HVAC |
U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test AP |
| HVAC |
U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test AQ |
| PCM |
P0532:00 |
A/C Refrigerant Pressure Sensor 'A' Circuit Low: No Sub Type Information |
GO to Pinpoint Test A |
| PCM |
P0533:00 |
A/C Refrigerant Pressure Sensor 'A' Circuit High: No Sub Type Information |
GO to Pinpoint Test A |
| PCM |
P0645:00 |
A/C Clutch Relay Control Circuit: No Sub Type Information |
GO to Pinpoint Test B |
| PCM |
P06A0:00 |
Variable A/C Compressor Control Circuit: No Sub Type Information |
GO to Pinpoint Test D |
| PCM |
P1464:00 |
A/C Demand Out Of Self Test Range: No Sub Type Information |
GO to Pinpoint Test M |
| PCM |
P193E:00 |
A/C Clutch Request Signal: No Sub Type Information |
GO to Pinpoint Test AB |
| PCM |
P2183:00 |
Engine Coolant Temperature Sensor 2 Circuit Range/Performance: No Sub Type Information |
GO to Pinpoint Test BE |
| PCM |
P2184:00 |
Engine Coolant Temperature Sensor 2 Circuit Low: No Sub Type Information |
GO to Pinpoint Test BE |
| PCM |
P2185:00 |
Engine Coolant Temperature Sensor 2 Circuit High: No Sub Type Information |
GO to Pinpoint Test BE |
| PCM |
P2186:00 |
Engine Coolant Temperature Sensor 2 Circuit Intermittent/Erratic: No Sub Type Information |
GO to Pinpoint Test BE |
| PCM |
P2600:00 |
Coolant Pump 'A' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test AH |
| PCM |
P2601:00 |
Coolant Pump 'A' Control Circuit Performance/Stuck Off: No Sub Type Information |
GO to Pinpoint Test AH |
| PCM |
P2602:00 |
Coolant Pump 'A' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test AH |
| PCM |
P2603:00 |
Coolant Pump 'A' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test AH |
| PCM |
P26BE:00 |
Engine Coolant Bypass Valve 'D' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test BJ |
| PCM |
P26BF:00 |
Engine Coolant Bypass Valve 'D' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test BJ |
| RHVAC |
B10B8:63 |
Push Buttons: Circuit/Component Protection Time-Out |
GO to Pinpoint Test AK |
| RHVAC |
U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test P |
| RHVAC |
U0164:00 |
Lost Communication With HVAC Control Module 'A': No Sub Type Information |
GO to Pinpoint Test R |
| RHVAC |
U0247:00 |
Lost Communication With Seat Control Module 'F': No Sub Type Information |
GO to Pinpoint Test U |
| RHVAC |
U0422:68 |
Invalid Data Received From Body Control Module: Event Information |
GO to Pinpoint Test AS |
| RHVAC |
U3000:41 |
Control Module: General Checksum Failure |
GO to Pinpoint Test AU |
| RHVAC |
U3000:42 |
Control Module: General Memory Failure |
GO to Pinpoint Test AU |
| RHVAC |
U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test AP |
| RHVAC |
U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test AQ |
| SOBDMC |
P01EB:96 |
Engine Coolant Heater 'A' Control Circuit Performance: Component Internal Failure |
GO to Pinpoint Test AM |
| SOBDMC |
P0531:00 |
A/C Refrigerant Pressure Sensor 'A' Circuit Range/Performance: No Sub Type Information |
GO to Pinpoint Test A |
| SOBDMC |
P0534:00 |
A/C Refrigerant System 'A' Charge Loss: No Sub Type Information |
GO to Pinpoint Test A |
| SOBDMC |
P0D6D:00 |
A/C Compressor 'A' Motor Voltage 'A' Low: No Sub Type Information |
GO to Pinpoint Test AL |
| SOBDMC |
P0D6F:00 |
A/C Compressor 'A' Motor Current High: No Sub Type Information |
GO to Pinpoint Test AL |
| SOBDMC |
P0D71:00 |
A/C Compressor Control Module Internal Temperature Sensor 'A' Performance: No Sub Type Information |
GO to Pinpoint Test AL |
| SOBDMC |
P2611:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test AV |
| SOBDMC |
P2612:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test AV |
| SOBDMC |
P2613:00 |
A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test AV |
| SOBDMC |
P26FD:00 |
A/C Compressor 'A' Internal Control Module Performance: No Sub Type Information |
GO to Pinpoint Test AL |
| SOBDMC |
P2D41:00 |
A/C Compressor 'A' Motor Voltage 'B' Performance: No Sub Type Information |
GO to Pinpoint Test AL |
| SOBDMC |
P2D42:00 |
A/C Compressor 'A' Motor Voltage 'B' Low: No Sub Type Information |
GO to Pinpoint Test AL |
| SOBDMC |
P2D44:00 |
A/C Compressor 'A' Motor Performance: No Sub Type Information |
GO to Pinpoint Test AL |
| SOBDMC |
P2DA4:00 |
Coolant Heater 'A' Internal Control Module Performance: No Sub Type Information |
GO to Pinpoint Test AM |
| SOBDMC |
P2DA5:00 |
Coolant Heater 'A' Supply Voltage Circuit: No Sub Type Information |
GO to Pinpoint Test AM |
| SOBDMC |
P2DA6:00 |
Coolant Heater 'A' Over Temperature: No Sub Type Information |
GO to Pinpoint Test AM |
| SOBDMC |
P2DA7:00 |
Coolant Heater 'A' Control Module System Voltage: No Sub Type Information |
GO to Pinpoint Test AM |
| SOBDMC |
P2E62:00 |
Engine Coolant Bypass Valve 'E' Control Circuit/Open: No Sub Type Information |
GO to Pinpoint Test AW |
| SOBDMC |
P2E63:00 |
Engine Coolant Bypass Valve 'E' Control Circuit Low: No Sub Type Information |
GO to Pinpoint Test AW |
| SOBDMC |
P2E64:00 |
Engine Coolant Bypass Valve 'E' Control Circuit High: No Sub Type Information |
GO to Pinpoint Test AW |
| SOBDMC |
U069E:81 |
Lost Communication with Coolant Heater 'B': Invalid Serial Data Received |
GO to Pinpoint Test AM |
| SOBDMC |
U069E:87 |
Lost Communication with Coolant Heater 'B': Missing Message |
GO to Pinpoint Test AM |