LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lincoln >> 2024 >> Nautilus Reserve >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> DTC Index (Acceleration Control - Engine Ignition YSTEM) >> Climate Control System DTCS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Climate Control System DTCS

Module DTC Description Action
ACCM B11EE:19 A/C Compressor: Circuit Current Above Threshold GO to Pinpoint Test X
ACCM B11EE:41 A/C Compressor: General Checksum Failure GO to Pinpoint Test AL
ACCM B11EE:4B A/C Compressor: Over Temperature GO to Pinpoint Test X
ACCM B11EE:92 A/C Compressor: Performance Or Incorrect Operation GO to Pinpoint Test X
ACCM P0562:00 System Voltage Low: No Sub Type Information GO to Pinpoint Test X
ACCM P0563:00 System Voltage High: No Sub Type Information GO to Pinpoint Test X
ACCM P0AFA:16 Hybrid/EV Battery System Voltage Low: Circuit Voltage Below Threshold GO to Pinpoint Test X
ACCM P0AFB:17 Hybrid/EV Battery System Voltage High: Circuit Voltage Above Threshold GO to Pinpoint Test X
ACCM P0AFB:1C Hybrid/EV Battery System Voltage High: Circuit Voltage Out Of Range GO to Pinpoint Test X
ACCM U0001:88 High Speed CAN Communication Bus: Bus Off GO to Pinpoint Test AA
ACCM U0100:00 Lost Communication With ECM/PCM 'A': No Sub Type Information GO to Pinpoint Test AB
ACCM U0111:00 Lost Communication With Battery Energy Control Module 'A': No Sub Type Information GO to Pinpoint Test AC
ACCM U0140:00 Lost Communication With Body Control Module: No Sub Type Information GO to Pinpoint Test AD
ACCM U3000:04 Control Module: System Internal Failure GO to Pinpoint Test AL
ACCM U3000:42 Control Module: General Memory Failure GO to Pinpoint Test AL
ACCM U3000:49 Control Module: Internal Electronic Failure GO to Pinpoint Test AL
BCMC P0EE3:00 A/C Refrigerant Distribution Valve 'B' Control Circuit/Open: No Sub Type Information GO to Pinpoint Test Z
BCMC P0EE4:00 A/C Refrigerant Distribution Valve 'B' Control Circuit Low: No Sub Type Information GO to Pinpoint Test Z
BCMC P0EE5:00 A/C Refrigerant Distribution Valve 'B' Control Circuit High: No Sub Type Information GO to Pinpoint Test Z
BCMC P2611:00 A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information GO to Pinpoint Test Y
BCMC P2612:00 A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information GO to Pinpoint Test Y
BCMC P2613:00 A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information GO to Pinpoint Test Y
BCMC P2CFC:00 A/C Clutch Control Circuit: No Sub Type Information GO to Pinpoint Test C
BCMC P2CFD:00 A/C Clutch Control Circuit Low: No Sub Type Information GO to Pinpoint Test C
BCMC P2CFE:00 A/C Clutch Control Circuit High: No Sub Type Information GO to Pinpoint Test C
HVAC B102E:11 Air Quality Sensor: Circuit Short To Ground GO to Pinpoint Test AP
HVAC B102E:15 Air Quality Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test AP
HVAC B102E:92 Air Quality Sensor: Performance Or Incorrect Operation GO to Pinpoint Test AP
HVAC B1081:07 Left Temperature Damper Motor: Mechanical Failure GO to Pinpoint Test N
HVAC B1081:11 Left Temperature Damper Motor: Circuit Short To Ground GO to Pinpoint Test N
HVAC B1081:12 Left Temperature Damper Motor: Circuit Short To Battery GO to Pinpoint Test N
HVAC B1081:13 Left Temperature Damper Motor: Circuit Open GO to Pinpoint Test N
HVAC B1082:07 Right Temperature Damper Motor: Mechanical Failure GO to Pinpoint Test O
HVAC B1082:11 Right Temperature Damper Motor: Circuit Short To Ground GO to Pinpoint Test O
HVAC B1082:12 Right Temperature Damper Motor: Circuit Short To Battery GO to Pinpoint Test O
HVAC B1082:13 Right Temperature Damper Motor: Circuit Open GO to Pinpoint Test O
HVAC B1083:07 Recirculation Damper Motor: Mechanical Failure GO to Pinpoint Test D
HVAC B1083:11 Recirculation Damper Motor: Circuit Short To Ground GO to Pinpoint Test D
HVAC B1083:12 Recirculation Damper Motor: Circuit Short To Battery GO to Pinpoint Test D
HVAC B1083:13 Recirculation Damper Motor: Circuit Open GO to Pinpoint Test D
HVAC B1086:07 Air Distribution Damper Motor: Mechanical Failure GO to Pinpoint Test E
HVAC B1086:11 Air Distribution Damper Motor: Circuit Short To Ground GO to Pinpoint Test E
HVAC B1086:12 Air Distribution Damper Motor: Circuit Short To Battery GO to Pinpoint Test E
HVAC B1086:13 Air Distribution Damper Motor: Circuit Open GO to Pinpoint Test E
HVAC B10AF:11 Blower Fan Relay: Circuit Short To Ground GO to Pinpoint Test P
HVAC B10AF:12 Blower Fan Relay: Circuit Short To Battery GO to Pinpoint Test Q
HVAC B10AF:13 Blower Fan Relay: Circuit Open GO to Pinpoint Test P
HVAC B10B3:11 Right Panel Air Discharge Temperature: Circuit Short To Ground GO to Pinpoint Test R
HVAC B10B3:15 Right Panel Air Discharge Temperature: Circuit Short To Battery Or Open GO to Pinpoint Test R
HVAC B10B5:11 Left Panel Air Discharge Temperature: Circuit Short To Ground GO to Pinpoint Test R
HVAC B10B5:15 Left Panel Air Discharge Temperature: Circuit Short To Battery Or Open GO to Pinpoint Test R
HVAC B10B8:63 Push Buttons: Circuit/Component Protection Time-Out GO to Pinpoint Test AT
HVAC B10B9:12 Blower Control: Circuit Short To Battery GO to Pinpoint Test P
HVAC B10B9:14 Blower Control: Circuit Short To Ground Or Open GO to Pinpoint Test P
HVAC B10B9:14 Blower Control: Circuit Short To Ground Or Open GO to Pinpoint Test Q
HVAC B11E5:11 Left HVAC Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test N
HVAC B11E5:15 Left HVAC Damper Position Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test N
HVAC B11E6:11 Right HVAC Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test O
HVAC B11E6:15 Right HVAC Damper Position Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test O
HVAC B11E7:11 Air Distribution Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test E
HVAC B11E7:15 Air Distribution Damper Position Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test E
HVAC B11F0:11 Air Intake Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test D
HVAC B11F0:15 Air Intake Damper Position Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test D
HVAC B12CA:11 Start/Stop 'Eco-Start' Status Indicator: Circuit Short To Ground GO to Pinpoint Test AR
HVAC B12CA:15 Start/Stop 'Eco-Start' Status Indicator: Circuit Short To Battery Or Open GO to Pinpoint Test AR
HVAC B162E:12 Max Defrost LED: Circuit Short To Battery GO to Pinpoint Test AS
HVAC B162E:14 Max Defrost LED: Circuit Short To Ground Or Open GO to Pinpoint Test AS
HVAC B16EE:01 Digital Scent Module: General Circuit/Electrical Failure GO to Pinpoint Test AU
HVAC B16EE:87 Digital Scent Module: Missing Message GO to Pinpoint Test AU
HVAC B16FD:07 Right Outboard Upper Horizontal Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B16FD:87 Right Outboard Upper Horizontal Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B16FE:07 Right Inboard Upper Vertical Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B16FE:87 Right Inboard Upper Vertical Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1701:07 Right Inboard Lower Horizontal Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1701:87 Right Inboard Lower Horizontal Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1702:07 Left Outboard Upper Vertical Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1702:87 Left Outboard Upper Vertical Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1703:07 Left Inboard Upper Vertical Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1703:87 Left Inboard Upper Vertical Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1704:07 Left Inboard Lower Horizontal Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1704:87 Left Inboard Lower Horizontal Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1707:07 Left Inboard Lower Vertical Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1707:87 Left Inboard Lower Vertical Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1708:07 Left Outboard Upper Horizontal Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1708:87 Left Outboard Upper Horizontal Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1709:07 Left Inboard Upper Horizontal Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1709:87 Left Inboard Upper Horizontal Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B170D:07 Right Inboard Lower Vertical Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B170D:87 Right Inboard Lower Vertical Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B170E:07 Right Outboard Upper Vertical Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B170E:87 Right Outboard Upper Vertical Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1712:07 Right Inboard Upper Horizontal Register Actuator: Mechanical Failure GO to Pinpoint Test AV
HVAC B1712:87 Right Inboard Upper Horizontal Register Actuator: Missing Message GO to Pinpoint Test AV
HVAC B1A61:11 Cabin Temperature Sensor: Circuit Short To Ground GO to Pinpoint Test S
HVAC B1A61:15 Cabin Temperature Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test S
HVAC B1A63:11 Right Solar Sensor: Circuit Short To Ground GO to Pinpoint Test T
HVAC B1A63:15 Right Solar Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test T
HVAC B1A64:11 Left Solar Sensor: Circuit Short To Ground GO to Pinpoint Test T
HVAC B1A64:15 Left Solar Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test T
HVAC B1A69:11 Humidity Sensor: Circuit Short To Ground GO to Pinpoint Test S
HVAC B1A69:15 Humidity Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test S
HVAC B1A69:92 Humidity Sensor: Performance Or Incorrect Operation GO to Pinpoint Test S
HVAC B1B71:11 Evaporator Temperature Sensor: Circuit Short To Ground GO to Pinpoint Test U
HVAC B1B71:15 Evaporator Temperature Sensor: Circuit Short To Battery Or Open GO to Pinpoint Test U
HVAC C1B14:11 Sensor Supply Voltage A: Circuit Short To Ground GO to Pinpoint Test K
HVAC C1B14:12 Sensor Supply Voltage A: Circuit Short To Battery GO to Pinpoint Test K
HVAC P24AE:09 Particulate Matter Sensor Circuit: Component Failure GO to Pinpoint Test AQ
HVAC P24AE:11 Particulate Matter Sensor Circuit: Circuit Short To Ground GO to Pinpoint Test AQ
HVAC P24AE:15 Particulate Matter Sensor Circuit: Circuit Short To Battery Or Open GO to Pinpoint Test AQ
HVAC P24AE:8F Particulate Matter Sensor Circuit: Erratic GO to Pinpoint Test AQ
HVAC P24AE:92 Particulate Matter Sensor Circuit: Performance Or Incorrect Operation GO to Pinpoint Test AQ
HVAC U0100:00 Lost Communication With ECM/PCM 'A': No Sub Type Information GO to Pinpoint Test AB
HVAC U0140:00 Lost Communication With Body Control Module: No Sub Type Information GO to Pinpoint Test AD
HVAC U0151:00 Lost Communication With Restraints Control Module: No Sub Type Information GO to Pinpoint Test AE
HVAC U0155:00 Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information GO to Pinpoint Test AF
HVAC U0253:00 Lost Communication With Accessory Protocol Interface Module: No Sub Type Information GO to Pinpoint Test AG
HVAC U0401:00 Invalid Data Received from ECM/PCM A: No Sub Type Information GO to Pinpoint Test AH
HVAC U0401:82 Invalid Data Received from ECM/PCM A: Alive/Sequence Counter Incorrect/Not Updated GO to Pinpoint Test AH
HVAC U0422:68 Invalid Data Received From Body Control Module: Event Information GO to Pinpoint Test AH
HVAC U0422:81 Invalid Data Received From Body Control Module: Invalid Serial Data Received GO to Pinpoint Test AH
HVAC U0452:82 Invalid Data Received From Restraints Control Module: Alive/Sequence Counter Incorrect/Not Updated GO to Pinpoint Test AH
HVAC U1000:00 Solid State Driver Protection Active -Driver Disabled: No Sub Type Information GO to Pinpoint Test AI
HVAC U2024:51 Control Module Cal-Config Data: Not Programmed GO to Pinpoint Test AK
HVAC U2100:00 Initial Configuration Not Complete: No Sub Type Information GO to Pinpoint Test AK
HVAC U3000:41 Control Module: General Checksum Failure GO to Pinpoint Test AL
HVAC U3000:49 Control Module: Internal Electronic Failure GO to Pinpoint Test AL
HVAC U3003:16 Battery Voltage: Circuit Voltage Below Threshold GO to Pinpoint Test AM
HVAC U3003:17 Battery Voltage: Circuit Voltage Above Threshold GO to Pinpoint Test AN
PCM P0532:00 A/C Refrigerant Pressure Sensor 'A' Circuit Low: No Sub Type Information GO to Pinpoint Test A
PCM P0533:00 A/C Refrigerant Pressure Sensor 'A' Circuit High: No Sub Type Information GO to Pinpoint Test A
PCM P0534:00 A/C Refrigerant System 'A' Charge Loss: No Sub Type Information GO to Pinpoint Test A
PCM P06A0:00 Variable A/C Compressor Control Circuit: No Sub Type Information GO to Pinpoint Test G
PCM P1464:00 A/C Demand Out Of Self Test Range: No Sub Type Information GO to Pinpoint Test M
PCM P193E:00 A/C Clutch Request Signal: No Sub Type Information GO to Pinpoint Test V
PCM P2519:00 A/C Request 'A' Circuit: No Sub Type Information GO to Pinpoint Test B
PCM P2520:00 A/C Request 'A' Circuit Low: No Sub Type Information GO to Pinpoint Test B
PCM P2600:00 Coolant Pump 'A' Control Circuit/Open: No Sub Type Information GO to Pinpoint Test AJ
PCM P2601:00 Coolant Pump 'A' Control Circuit Performance/Stuck Off: No Sub Type Information GO to Pinpoint Test AJ
PCM P2602:00 Coolant Pump 'A' Control Circuit Low: No Sub Type Information GO to Pinpoint Test AJ
PCM P2603:00 Coolant Pump 'A' Control Circuit High: No Sub Type Information GO to Pinpoint Test AJ
SOBDMC P0531:00 A/C Refrigerant Pressure Sensor 'A' Circuit Range/Performance: No Sub Type Information GO to Pinpoint Test A
SOBDMC P0534:00 A/C Refrigerant System 'A' Charge Loss: No Sub Type Information GO to Pinpoint Test A
SOBDMC P0D6D:00 A/C Compressor 'A' Motor Voltage 'A' Low: No Sub Type Information GO to Pinpoint Test X
SOBDMC P0D6F:00 A/C Compressor 'A' Motor Current High: No Sub Type Information GO to Pinpoint Test X
SOBDMC P0D71:00 A/C Compressor Control Module Internal Temperature Sensor 'A' Performance: No Sub Type Information GO to Pinpoint Test X
SOBDMC P0EE3:00 A/C Refrigerant Distribution Valve 'B' Control Circuit/Open: No Sub Type Information GO to Pinpoint Test Z
SOBDMC P0EE4:00 A/C Refrigerant Distribution Valve 'B' Control Circuit Low: No Sub Type Information GO to Pinpoint Test Z
SOBDMC P0EE5:00 A/C Refrigerant Distribution Valve 'B' Control Circuit High: No Sub Type Information GO to Pinpoint Test Z
SOBDMC P2611:00 A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information GO to Pinpoint Test Y
SOBDMC P2612:00 A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information GO to Pinpoint Test Y
SOBDMC P2613:00 A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information GO to Pinpoint Test Y
SOBDMC P26FD:00 A/C Compressor 'A' Internal Control Module Performance: No Sub Type Information GO to Pinpoint Test X
SOBDMC P2D41:00 A/C Compressor 'A' Motor Voltage 'B' Performance: No Sub Type Information GO to Pinpoint Test X
SOBDMC P2D42:00 A/C Compressor 'A' Motor Voltage 'B' Low: No Sub Type Information GO to Pinpoint Test X
SOBDMC P2D44:00 A/C Compressor 'A' Motor Performance: No Sub Type Information GO to Pinpoint Test X