Function Test
Start engine to supply vacuum to actuator diaphragm. Observe actuator arm when battery voltage is connected across specified terminals of actuator connector. SeeFigure . If actuator arm does not function as specified, replace actuator.
ACTUATOR FUNCTION TEST
| Application (Terminals) | Actuator Arm Result |
|---|---|
| Apply 12 Volts To "C" & Ground "A", "B" & "D" | Pull |
| Apply 12 Volts To "C" & Ground "A" & "D" | Hold |
| Apply 12 Volts To "C" & Ground "A" | Extend |
| Disconnect All Voltage & Ground | Release |