Main Switch
Disconnect main switch connector. With main switch in specified position, check continuity between main switch connector terminals. See MAIN SWITCH CONTINUITY TEST . SeeFig 1 . If continuity is not as specified, replace main switch.
MAIN SWITCH CONTINUITY TEST
| Switch Position | Continuity Between Terminals | ||
|---|---|---|---|
| Normal | "B" & "F"; (1) "A" & "H"; (1) "D" & "G" | ||
| CRUISE MAIN | "B", "F" & "H"; (1) "A" & "H"; (1) "D" & "G" | ||
| OFF | (1) "A" & "H"; (1) "D" & "G" | ||
|
|||