Component Testing: Sub-Switch
Check continuity across specified terminals of sub-switch connector with main switch button held in specified position. See SUB-SWITCH CONTINUITY TEST table. SeeFigure . Replace sub-switch if continuity is not as specified.
SUB-SWITCH CONTINUITY TEST
| Application & Switch Position | Continuity Between Terminals | ||
|---|---|---|---|
| UP | No. 1 & 5; 3 & 4 ((1) 2) | ||
| Off (Neutral) | No. 1 & 2; 3 & 4 ((1) 5) | ||
| DOWN | No. 1 & 2; 4 & 5 ((1) 3) | ||
|
|||