Door Lock Timer Unit
- Remove door lock timer unit. Set ohmmeter on X1000 scale. Check continuity between specified terminals of door lock timer unit. See DOOR LOCK TIMER UNIT TEST table. SeeFig 1.
- If continuity is not as specified, replace door lock timer unit. If continuity is as specified, apply battery voltage across terminals "B" (positive) and "A" (negative). Connect jumper wire between terminals "H" and "D", or "H" and "C". Listen if door lock timer unit clicks. Replace door lock timer unit if it does not click.
DOOR LOCK TIMER UNIT TEST
| Continuity Between Terminals | No Continuity Between Terminals |
|---|---|
| "A" & "C" | "A" & "B" |
| "A" & "D" | "A" & "H" |
| "A" & "E" | "B" & "C" |
| "A" & "F" | "B" & "D" |
| "B" & "H" | "B" & "E" |
| "C" & "D" | "B" & "F" |
| "C" & "E" | "C" & "H" |
| "C" & "F" | "D" & "H" |
| "D" & "E" | "E" & "H" |
| "D" & "F" | "F" & "H" |