LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 1998 >> 626 DX L4-2.0L DOHC >> Repair and Diagnosis >> Specifications >> Electrical Specifications >> Charging System >> System Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

System Specifications

Charging System Specifications
Battery
Test Load Chart
Battery Load (A)
GROUP 36R 240
Battery Positive Voltage With Load
Approximate Battery Temperature Minimum Voltage (V)
21 degrees C (70 degrees F) 9.6
15 degrees C (60 degrees F) 9.5
10 degrees C (50 degrees F) 9.4
4 degrees C (40 degrees F) 9.3
-1 degrees C (30 degrees F) 9.1
-7 degrees C (20 degrees F) 8.9
-12 degrees C (10 degrees F) 8.7
-18 degrees C (0 degrees F) 8.5
Dark Current 20 mA Max.
Charging Current
Battery Type (5 Hour Rate) Slow Charge (A) Quick Charge (A)
GROUP 36R (48) 4.5-5.5 30
Battery Positive Voltage After Charge Above 12.4 V
Generator
Standard Voltage
Terminal Ignition Switch: ON Idle (V)
At 20 degrees C (68 degrees F).
B B+ 14.1-14.7 V
L Approximately 1 V 13.2-13.8 V
S B+ 14.1-14.7 V
Standard Current (Referance)
Engine Speed (RPM) Terminal B Current (A)
1,000 Approximately 58 or below
Must not be 0.
2,000 Approximately 77 or below
Must not be 0.