Power Window Main Switch Inspection
- Inspect for continuity between the terminals of the power window main switch connector with the main switch in the following positions.
- When inspecting the driver's side, connect the B+ to terminal H and connect the GND to the terminal F.
- If not as specified, replace the power window main switch.