Door Lock Control Module Inspection: Notes
- Remove the lower panel.
- Measure the voltage at the door lock control module terminals as indicated.
- Disconnect the door lock control module connector before inspecting for continuity at terminals F, H, M and N.
- If not as specified, inspect the parts listed under "Action" and the related wiring harnesses.
- If the parts and wiring harnesses are okay but the system still does not work properly, replace the door lock control module.