Keyless Control Module Inspection: Notes
- Pull out the keyless control module with the connector connected.
- Measure the voltage at the keyless control module terminals (other than terminal L) as indicated.
- If not as specified, inspect the parts listed under "Action."
- Disconnect the negative battery cable.
- Disconnect the keyless control module connector and inspect for continuity between terminal L and bracket.
- Inspect for continuity at terminal L as indicated.
- If the parts and wiring harnesses are okay but the system still does not work properly, perform the troubleshooting.