DTC P0711: Notes
DTC P0711 DETECTION CONDITION AND POSSIBLE CAUSES
| DTC P0711 |
Transaxle fluid temperature (TFT) sensor malfunction (stuck) |
| DETECTION CONDITION |
- TFT sensor signal stays outside normal temperature range for 10 minutes or more.
Diagnostic support note:
- This is a continuous monitor (CCM).
- MIL illuminates if TCM detects the above malfunction conditions in two consecutive drive cycles.
- PENDING CODE is available.
- FREEZE FRAME DATA is available.
- O/D OFF indicator light does not flash.
- DTC is stored in TCM memory.
|
| POSSIBLE CAUSE |
- TFT sensor malfunction
- Connector corrosion
- TCM malfunction
|