Flasher Control Module Inspection: Notes
- Remove the flasher control module with the connector still connected.
- Measure the voltage at each terminal (other than terminal F).
- Disconnect the flasher control module connector.
- Verify that continuity at terminal F is as indicated in TERMINAL VOLTAGE TABLE
.
- If there is any malfunction, inspect the parts under "Inspection item(s)".
- If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the flasher control module.