If simulation function of M-MDS is used:
- Start the engine and run it is idling.
- Disconnect the hose between the wastegate control solenoid valve and the intake pipe.
- Put a finger to the wastegate control solenoid valve and verify that there is no pressure applied.
- If there is pressure, inspect the following:
- Wiring harness and connectors (Wastegate control solenoid valve-PCM terminal 2AA)
- Wastegate control solenoid valve (Stuck open)
- If there is pressure, inspect the following:
- Warm up the engine to normal operating temperature.
- Connect the M-MDS to the DLC-2 and verify that DTC P0245 or P0246 are shown. Perform the DTC inspection.
(See DTC P0245 .)
(See DTC P0246 .)
- Select the VGT PID.
- Increase the duty value of the wastegate control solenoid valve and inspect if the operation sound of the solenoid valve is heard.
- If the operation sound is heard, inspect for loose or damaged vacuum hoses. (Wastegate actuator - wastegate control solenoid valve - intake hose)
- If the operation sound is not heard, perform the wastegate control solenoid valve inspection.
- Warm up the engine to normal operating temperature.
- Monitor the VGT and APP PIDs using the M-MDS.
- Run the engine with the APP PID above 30%
and verify that the VGT PID value increases from 0%
.
- If the VGT PID is 0% , inspect the APP PID.