Security Access Procedure
NOTE:
- When using the SST (M-MDS) to perform "Ignition Key Code Erase" or "Customer Spare Key Programming Enable/Disable", it is necessary to obtain security access approval.
- Connect the SST (M-MDS).
- Select "Tool box", "Body", "Security", and then "PATS Functions" (in this order).
- The SST
(M-MDS) will read out an outcode depending on the designated procedure.CAUTION:
- After reading out the outcode, do not turn ignition switch from LOCK to ON position 5 times, otherwise the outcode value will be changed.
- Access the Mazda official website to obtain the incode that corresponds to the outcode.
- Input the incode to the SST (M-MDS).
- Verify that the security access procedure finishes normally.