Diagnostic Monitoring Test Results Table: Notes
DIAGNOSTIC MONITORING TEST RESULTS
| Module ID h (1) | Test ID h (1) | Component ID h (1) | Test Description | ||||
|---|---|---|---|---|---|---|---|
| Oxygen Sensor Monitor (01-OF) | |||||||
| 10 | 01 | 11 | Sensor voltage amplitude - bank 1, sensor 1 | ||||
| 10 | 01 | 21 | Sensor voltage amplitude - bank 2, sensor 1 | ||||
| 10 | 02 | 11 | Upstream static shift, lean shift on EGO 11 | ||||
| 10 | 02 | 11 | Upstream static shift, rich shift on EGO 11 | ||||
| 10 | 02 | 21 | Upstream static shift, lean shift on EGO 21 | ||||
| 10 | 02 | 21 | Upstream static shift, rich shift on EGO 21 | ||||
| 10 | 03 | 01 | Upstream switchpoint | ||||
| 10 | 03 | 02 | Downstream switchpoint | ||||
| Catalyst Monitor (10-1F) | |||||||
| 10 | 10 | 11 | Rear to front switch ratio test - bank 1 test | ||||
| 10 | 10 | 21 | Rear to front switch radio test - bank 2 test | ||||
| Evaporative Monitor (21-2F) | |||||||
| 10 | 21 (2) | 00 | Fuel tank pressure test - low | ||||
| 10 | 21 (2) | 00 | Fuel tank pressure test - high | ||||
| 10 | 22 (2) | 00 | Evap-phase 2 change in pressure test | ||||
| 10 | 23 (2) | 00 | Evap-phase 4 change in pressure too large | ||||
| 10 | 24 (2) | 00 | Evap-phase 4 change in pressure too small | ||||
| 10 | 25 (2) | 00 | Evap-phase 4 pressure build test-upper limit | ||||
| 10 | 26 | 00 | Phase 0 initial tank vacuum and minimum limit | ||||
| 10 | 26 | 00 | Phase 0 initial tank vacuum and maximum limit | ||||
| 10 | 27 | 00 | Phase 2 0.040" cruise leak check vacuum bleed-up and max 0.04" leak threshold | ||||
| 10 | 28 | 00 | Phase 2 0.020" cruise leak check vacuum bleed-up and max leak threshold | ||||
| 10 | 29 | 00 | EVAP-phase 4 change in pressure too small | ||||
| 10 | 2A | 00 | Phase 4 vapor generation maximum change in pressure and maximum threshold | ||||
| 10 | 2B | 00 | Phase 4 vapor generation maximum absolute pressure and maximum threshold | ||||
| 10 | 2C | 00 | Phase 2 0.020" idle leak check vacuum bleed-up and max leak threshold | ||||
| 10 | 2D | 00 | Phase 2 0.040" idle leak check vacuum bleed-up and max no-leak threshold | ||||
| EGR System Monitor (41-4F) | |||||||
| 10 | 41 (2) | 11 | Upstream hose disconnected test | ||||
| 10 | 41 (2) | 12 | Downstream hose disconnected test | ||||
| 10 | 45 | 20 | Stuck open valve test | ||||
| 10 | 49 | 30 | EGR flow test | ||||
| 10 | 4B | 30 | Flow test | ||||
| Misfire Monitor (51-5F) | |||||||
| 10 | 50 | 00 | Total misfires that exceeded threshold | ||||
| 10 | 51 | 01 | Cylinder #1 misfires that exceeded threshold | ||||
| 10 | 51 | 02 | Cylinder #2 misfires that exceeded threshold | ||||
| 10 | 51 | 03 | Cylinder #3 misfires that exceeded threshold | ||||
| 10 | 51 | 04 | Cylinder #4 misfires that exceeded threshold | ||||
| 10 | 51 | 05 | Cylinder #5 misfires that exceeded threshold | ||||
| 10 | 51 | 06 | Cylinder #6 misfires that exceeded threshold | ||||
| 10 | 52 | 00 | Consecutive cylinder events during active test | ||||
| 10 | 53 | 01 | Misfire rate per 200 revs for cylinder 1/type A | ||||
| 10 | 53 | 02 | Misfire rate per 200 revs for cylinder 2/type A | ||||
| 10 | 53 | 03 | Misfire rate per 200 revs for cylinder 3/type A | ||||
| 10 | 53 | 04 | Misfire rate per 200 revs for cylinder 4/type A | ||||
| 10 | 53 | 05 | Misfire rate per 200 revs for cylinder 5/type A | ||||
| 10 | 53 | 06 | Misfire rate per 200 revs for cylinder 6/type A | ||||
| 10 | 54 | 00 | Highest misfire rate in 200 rev test/type A | ||||
| 10 | 55 | 00 | Highest misfire rate in 1, 000 rev test/type B | ||||
| 10 | 56 | 00 | Misfire monitor trip complete test | ||||
The conversion is done as follows: If the value is > 32767 then complement (change 0's to 1's and 1's to 0's), add 1 and a negative sign. |
|||||||
Example:
SIGNED VALUES CONVERSION EXAMPLE
| 50000= | 110000110101000 |
|---|---|
| Complement of 50000= | 0011110010101111 |
| +1 | |
| 001111001010000 | |
| Signed Value= | -15536 |