LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2007 >> RX-8 Sport, 1.3 3 >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Neutral Switch Inspection >> Continuity Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Continuity Inspection

  1. Remove the neutral switch.
  2. Verify that the continuity between neutral switch terminals 1A and 2A is as indicated in MEASUREMENT CONDITION AND CONTINUITY CHART .
    • If there is no malfunction, perform the "CIRCUIT OPEN/SHORT INSPECTION ".
    • If there is any malfunction, replace the neutral switch.
      Fig 1: Inspecting Continuity Between Neutral Switch Terminals 1A & 2A
      G04562996Courtesy of MAZDA MOTORS CORP.
MEASUREMENT CONDITION AND CONTINUITY CHART

Measurement condition Continuity
Push the rod. No continuity
Except above Continuity detected