LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2008 >> Tribute Hybrid Touring, AWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Control System - Hybrid >> Reference Values >> 2.3L 4V Tribute Hybrid >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

DIAGNOSTIC REFERENCE VALUES

PCM Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
A/CT B1 2.6-2.9/89-102 2.6-2.9/89-102 2.6-2.9/89-102 2.6-2.9/89-102 DCV/DEG F
APP1 B5 4.1 4.1 3.6-4.1 3.6-4.1 DCV
BOO B8 OFF ON OFF OFF ON-OFF
FTP B9 2.6/0 2.6/0 2.6/0 2.6/0 DCV/PSI
APP2 B17 1.5 1.5 1.5-2.0 1.5-2.4 DCV
BPO_Hz/BPO B24 2/NO 6/YES (I) 2/NO 2/NO Hz/YES-NO
APP3 B28 0.9 0.9 0.9-1.3 0.9-1.8 DCV
MAF B32 0 1.21 1.53 1.0 DCV
IAT (G) B39 2.47/91.4 2.93/73.4 3.57/50.0 3.59/48.2 DCV/DEG F
FRT (G) E6 2.26/102.2 2.15/105.8 3.18/69.8 3.19/69.8 DCV/DEG F
TP2 E8 0.06 0.84 1.27 1.66 DCV
TP1 E19 3.35 4.28 4.11 3.87 DCV
MAP E23 4.01/1/14.35 1.71/58/6.09 2.26/44/8.12 2.91/28/10.44 DCV/kPa/PSI
FRP E27 2.72/38.94 2.74/39.29 2.73/39.12 2.81/40.32 DCV/PSI
O2S11 (C) E30 0 Switching Switching Switching DCV
CHT (G) E33 0.71/183.2 0.63/190.4 3.42/210.2 3.21/222.8 DCV/DEG F
O2S12 (D) E42 0.04 0.07 0.77 0.66 DCV
MECT_V T3 2.6 2.6 3.3 3.2 DCV
GTQ_CMD T5 300/0 295-300/(-)5-0 270-300/(-)22-0 270-300/(-)22-0 Hz/Lb-ft
MTQ_OUT T7 -0.2 -7.5 0.2 -9.9 Nm
TR_A1 T16 4.29 (H) 4.29 (H) 3.73 (Q) 3.74 (Q) DCV
TR_A2 T28 1.01 (H) 1.01 (H) 3.73 (Q) 3.73 (Q) DCV
DCE T34 ON ON ON ON ON - OFF
TR_A3 T39 0.63 (H) 0.63 (H) 3.35 (Q) 3.35 (Q) DCV
ACCS PID OFF OFF OFF OFF ON-OFF
APP PID 0 0 19.5 0 %
BARO PID 155.8/14.24 155.8/14.24 156.2/14.3 156.6/14.36 Hz/PSI
DEL_MOD_V PID 0.06 0.06 0 0.06 DCV
ENG_TQ PID 1047 66.79 297.9 854 Nm
ETC_ATC PID 0.09 3.71 13.77 9.14 DEGREES
FLI PID 86 86 90 95.71 %
HTRCM11 PID 1.64 1.64 1.49 1.49 AMP
HTRCM12 PID 762 762 590 590 mA
KEYST PID RUN RUN RUN RUN KEY POSITION
SHRFT1 PID 0 -0.54 -1.97 -2.02 %
LOAD PID 50.04 19.95 28.29 35.86 %
RPM PID 0 1087 1486 2267 RPM
DIAGNOSTIC REFERENCE VALUES

PCM Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
FP B12 OFF/75 OFF/23 OFF/24 OFF/25 ON - OFF/%
EVAPCV B13 OFF/0 OFF/0 OFF/0 OFF/0 ON - OFF/%
PSR B27 ON ON ON ON ON-OFF
FTIV B29 100 0 100 0 %
EVMV B34 OFF/0 VARYING/560 VARYING/0 VARYING/816 STATUS/mA
HFC B37 OFF ON (B) OFF OFF ON-OFF
LFC B38 OFF ON (B) OFF OFF ON-OFF
HTR11 E49 OFF ON ON ON ON-OFF
HTR12 E50 OFF ON ON ON ON-OFF
MECP T4 ON ON ON ON ON-OFF
ACRDV T22 OFF OFF OFF OFF ON-OFF
HPUMP T23 OFF ON(O) OFF OFF ON-OFF
EGRMDSD PID 1 1 21 23 STEP
ENGRPMA PID 0 1061 1238 2113 RPM
ETC_DSD PID 0 3.7 13.89 9.27 DEGREES
FRP_DSD PID 39.68 39.68 40.07 40.42 PSI
FTP_H2O PID 0.03 -0.06 -0.03 -0.2 in H2O
G_SDN PID NO YES (L) NO NO YES-NO
G_SPEED PID 0 3663 -475 -1036 RPM
GTQ PID 0 0 -0.1 -0.1 Nm
LONGFT1 PID 3.51 3.51 1.95 0 %
MCF PID OFF OF OFF OFF ON - OFF
M_SDN PID NO YES (M) NO NO YES-NO
MTO PID 0 0 0 0 Nm
SPARKADV PID 10 1.25 29.25 32.75 DEGREES
TOT PID 113 113 129.2 129.2 DEG F
DIAGNOSTIC REFERENCE VALUES

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR B35/B36 13.75 13.69 13.81 13.81 DCV
VREF B40/E40 5 5 5 5 DCV