No.4 Changing the Method for Registering Additional Keys: Procedure
- Using any key, turn the ignition switch to the ON position. (Either a valid or an unregistered key can be used.)NOTE:
- When using an unregistered key, although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
- Connect the M-MDS to the DLC-2.
- After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
- Select the "Body".
- Select the "Security".
- Select the "PATS Functions".
- When using the PDS (Pocket PC)
- Select the "Programming".
- Select the "PATS Functions".
- When using the IDS (laptop PC)
- Then, select an item from the screen menu. "Customer Spare Key Programming Enable" or "Customer Spare Key Programming Disable".
- Perform the procedure according to the directions on the screen.
- Perform security access as indicated on the M-MDS screen. (See NO.6 SECURITY ACCESS PROCEDURE .)
- Select either "Customer Spare Key Programming Enable" or "Customer Spare Key Programming Disable" from the M-MDS screen menu. Depending on the selected menu, the additional key registration method is as shown below:ADDITIONAL KEY REGISTRATION METHOD
Setting Additional key registration method Procedure using two valid keys Procedure using the M-MDS Customer spare key programming enable X X Customer spare key programming disable - X x : Procedure is possible - : Procedure is not possible - After verifying that the PATS function menu is displayed again on the M-MDS screen, select "Exit" to complete the M-MDS function.
- After Step 9, wait 10 s or more and then turn the ignition switch to the LOCK position.