LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2009 >> 5 Touring, 2.3 L >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Security System And Locks System >> Immobilizer System Component Replacement/Key Addition And Clearing [Keyless Entry System] >> No.4 Changing the Method for Registering Additional Keys >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

No.4 Changing the Method for Registering Additional Keys: Procedure

  1. Using any key, turn the ignition switch to the ON position. (Either a valid or an unregistered key can be used.)
    NOTE:
    • When using an unregistered key, although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
  2. Connect the M-MDS to the DLC-2.
  3. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
    • When using the IDS (laptop PC)
      1. Select the "Body".
      2. Select the "Security".
      3. Select the "PATS Functions".
    • When using the PDS (Pocket PC)
      1. Select the "Programming".
      2. Select the "PATS Functions".
  4. Then, select an item from the screen menu. "Customer Spare Key Programming Enable" or "Customer Spare Key Programming Disable".
  5. Perform the procedure according to the directions on the screen.
  6. Perform security access as indicated on the M-MDS screen. (See NO.6 SECURITY ACCESS PROCEDURE .)
  7. Select either "Customer Spare Key Programming Enable" or "Customer Spare Key Programming Disable" from the M-MDS screen menu. Depending on the selected menu, the additional key registration method is as shown below:
    Fig 1: View Of DLC-2 Connector
    G05543510Courtesy of MAZDA MOTORS CORP.
    ADDITIONAL KEY REGISTRATION METHOD

    Setting Additional key registration method
    Procedure using two valid keys Procedure using the M-MDS
    Customer spare key programming enable X X
    Customer spare key programming disable - X
    x : Procedure is possible
    - : Procedure is not possible
  8. After verifying that the PATS function menu is displayed again on the M-MDS screen, select "Exit" to complete the M-MDS function.