LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2011 >> CX-9 Sport, 3.7 V, AWD >> Repair and Diagnosis >> Engine Performance >> System >> On-Board Diagnostic - Engine Control System (Introduction) >> OBD-II Drive Mode
April 5, 2026: LEMON Manuals is launched! Read the announcement.

OBD-II Drive Mode

OBD-II MONITORS PROCEDURE CHART

OBD-II monitor exercised Step Procedure Purpose
Drive Mode Preparation 1
NOTE:
  • To bypass the EVAP soak timer (normally 6 hours), the PCM must remain powered after clearing the continuous DTCs and resetting the emission monitors information in the PCM.
  • Connect the M-MDS to the DLC-2.
  • Turn the ignition switch to the ON position (Engine off).
  • Turn the ignition switch off then to the ON position, (Engine off).
  • Select the appropriate vehicle and engine qualifier.
  • Clear the continuous DTCs and reset the emission monitors information in the PCM.
NOTE:
  • The following events occur when the continuous DTCs and the emission monitors information is cleared from the PCM:
    • Clears the number of DTCs and the DTCs.
    • Clears the freeze frame data.
    • Clears the diagnostic monitoring test results.
    • Clears the status of the OBD-II system monitors is reset.
    • Sets DTC P1000.
Bypasses the engine soak timer. Resets the OBD-II monitor status.
2
  • Start the engine without turning the ignition switch off.
3
  • Idle the engine for 15 s  .
  • Drive at 72 km/h {45 mph}  until the ECT is 76.7 °C {170 °F} or more. 
Prep for Monitor Entry 4
NOTE:
  • When the IAT is not within 4.4-37.8 °C {40-100 °F}  or the altitude is above 2,438 m {8,000 ft}  , the EVAP monitor will not run.
  • Is the IAT within 4.4-37.8 °C {40-100 °F}? 
    • If not within the specification, complete the following steps but, note that step 14 will be required to "bypass" the EVAP monitor.
Engine warm-up and provides IAT input to the PCM.
HO2S 5
  • Cruise at 72 km/h {45 mph}  for up to 5 min. 
Executes the HO2S monitor.
EVAP 6
NOTE:
  • To initiate the monitor, the throttle should be at part throttle, Evaporative Emissions Duty Cycle must be more than 75%, and FLI must be 15- 85%, and for fuel tanks over 25 gallons Fuel Level Indicator Input must be 30-85%.
  • Cruise at 72-104 km/h {45-65 MPH}  for 10 min. 
Executes the EVAP emission monitor.
Catalyst 7
  • Stop the vehicle and go to traffic conditions.
  • Include five different constant cruise speeds, ranging from 40-72 km/h {25-44 mph} over a 10 min  period.
Executes the catalyst efficiency monitor.
EGR 8
  • Stop the vehicle and go to traffic conditions.
  • Idle the engine for 30 s.
  • Accelerate to 72km/h {45mph}  at 50-75% throttle, cruise at steady throttle for 1 min  .
  • Repeat idle, acceleration and cruise 3 times.
Executes the EGR monitor.
CCM (Engine) 9
  • Stop the vehicle.
  • Idle the engine for 2 min  with the selector lever in the D range.
Executes the idle air control portion of the CCM.
CCM (Transaxle) 10
  • Stop the vehicle.
  • In overdrive, moderately accelerate to 81 km/h {50 mph} and cruise for 15 s or more  .
  • Stop the vehicle and repeat without overdrive to 64 km/h {40 mph}  cruising for 30 s or more  .
  • While at 64 km/h {40 mph}  , activate overdrive and accelerate to 81 km/h {50 mph}  and cruise for 15 s or more  .
  • Stop the vehicle for 20 s or more  .
  • Repeat Step 10 five times.
Executes the transaxle portion of the CCM.
Misfire, Fuel and HO2S Monitors 11
  • Stop the vehicle.
  • Accelerate to 104 km/h {60 mph}  , hold steady throttle for 5 s.
  • Decelerate at closed throttle until reaching 64 km/h {40 mph}  (no brakes).
  • Accelerate from 64 km/h {40 mph}  to 104 km/h {65 mph}  hold steady throttle for 5 s.
  • Repeat 5 times.
Allows learning for the misfire monitor.
Readiness Check 12
  • Access the ON BOARD SYSTEM READINESS to verify the OBD-II monitoring status.
    • If completed, all of the OBD-II monitoring status items change from non-completed to completed.
    • If not completed, go to the next step.
Determines if any monitor has not been completed.
Pending Code Check and EVAP Monitor Bypass Check 13
  • Verify that no pending code has been stored. If any pending code has been stored, perform the appropriate DTC inspection. (See DTC TABLE .)
  • Otherwise, return any incomplete monitor.
NOTE:
  • If the EVAP monitor is not completed and the IAT was out of the 4.4-37.8 °C {40-100 °F}  range, or the altitude is above 2,438 m {8,000 ft}  , the "EVAP Monitor Bypass" procedure must be followed.
  • Perform the "EVAP Monitor Bypass" procedure.
NOTE:
  • The DTC P1000 will be stored if any of the OBD-II monitors does not complete.
Determines if a pending code is preventing the clearing of the DTC P1000.
EVAP Monitor Bypass 14
  • Leave the vehicle for 8 h  .
  • Go to Step 2 then perform from Step 2 to 11.
Allows the "bypass" counter to increment to two.