Diagnostic Procedure
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT RELAY
|
Yes | Replace the starter relay, then go to Step 8. |
| No | Go to the next step. | ||
| 2 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 8. |
| No | Go to the next step. | ||
| 3 | INSPECT STARTER RELAY CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to Step 8. |
| No | Go to the next step. | ||
| 4 | INSPECT PCM CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 8. |
| No | Go to the next step. | ||
| 5 | INSPECT STARTER RELAY CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to Step 8. |
| No | Go to the next step. | ||
| 6 | INSPECT PCM
|
Yes | Go to the next step. |
| No | Replace the PCM, then go to Step 8. (See PCM REMOVAL/INSTALLATION [MZR 2.5] .) |
||
| 7 | INSPECT KEYLESS CONTROL MODULE
|
Yes | Go to the next step. |
| No | Replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
||
| 8 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 9 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT RELAY
|
Yes | Replace the starter relay, then go to Step 8. |
| No | Go to the next step. | ||
| 2 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 8. |
| No | Go to the next step. | ||
| 3 | INSPECT STARTER RELAY CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to Step 8. |
| No | Go to the next step. | ||
| 4 | INSPECT PCM CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 8. |
| No | Go to the next step. | ||
| 5 | INSPECT STARTER RELAY CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to Step 8. |
| No | Go to the next step. | ||
| 6 | INSPECT PCM
|
Yes | Go to the next step. |
| No | Replace the PCM, then go to Step 8. (See PCM REMOVAL/INSTALLATION [MZR 2.5] .) |
||
| 7 | INSPECT KEYLESS CONTROL MODULE
|
Yes | Go to the next step. |
| No | Replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
||
| 8 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 9 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT RELAY
|
Yes | Replace the relay, then go to Step 7. |
| No | Go to the next step. | ||
| 2 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 7. |
| No | Go to the next step. | ||
| 3 | INSPECT PCM CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 7. |
| No | Go to the next step. | ||
| 4 | INSPECT STARTER RELAY CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to Step 7. |
| No | Go to the next step. | ||
| 5 | INSPECT PCM
|
Yes | Go to the next step. |
| No | Replace the PCM, then go to Step 7. (See PCM REMOVAL/INSTALLATION [MZI 3.7 V6] .) |
||
| 6 | INSPECT KEYLESS CONTROL MODULE
|
Yes | Go to the next step. |
| No | Replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
||
| 7 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 8 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||