Using M-MDS
- Connect the M-MDS to DLC-2.
- After the vehicle is identified, select the following items from the initial screen of the M-MDS.
- Select the "Module Programming".
- Select "Programmable Parameters".
- Select menu in the SSU.
- Select an item name, and then select option.
| M-MDS display | Function | Initial setting | Setting contents | Control unit |
|---|---|---|---|---|
| Unlock Mode (Without Touch Sensor) | 2-step unlocking system can be set. | Once Driver's, Twice: All Doors. | Not Adopted./Touch Once: ALL Doors./Once Driver's, Twice: All Doors. | Start stop unit |
- For the auto door lock function, refer to the personalization features for the RBCM. (See CONTROL SYSTEM PERSONALIZATION FEATURES SETTING PROCEDURE ).