Diagnostic Procedure
AUTO OPEN/CLOSE FUNCTION DIAGNOSTIC PROCEDURE
| STEP |
INSPECTION |
ACTION |
| 1 |
- Switch the ignition to off (LOCK) for 3 min.
- Switch the ignition ON (engine off or on).
- Initialize the power window system.
- Operate the auto open/close function.
- Dose the power window operate properly?
|
Yes |
System is normal. The power window system auto open/close function dose not operate temporarily for any of the following reasons:
- The power window switch is operated while the power window motor protection circuit (integrated in power window motor) is operating.
- The power window main switch power supply is cut off by disconnection of the negative battery cable or removing the fuse.
|
| No |
Go to the next step. |
| 2 |
- Does the sensor built into the power window motor send pulse signals while the power window motor is operating?
- Inspect the voltage at the following power window motor terminals:
- B (sensor 1 signal)
- A (sensor 2 signal)
- Is the voltage approx. 6 V
?
|
Yes |
Go to the next step. |
| No |
Replace the power window motor. (See
POWER WINDOW MOTOR REMOVAL/INSTALLATION
.) |
| 3 |
- Does the sensor built into the power window motor send pulse signals while the power window motor is operating?
- Inspect the voltage at the following power window main switch (14-pin connector) terminals:
- 2D (sensor 1 signal)
- 2F (sensor 2 signal)
- Is the voltage approx. 6 V
?
|
Yes |
Replace the power main switch. (See
POWER WINDOW MAIN SWITCH REMOVAL/INSTALLATION
.) |
| No |
Inspect for an open or short circuit in wiring between the power window motor (sensor) and the power window main switch. Inspect the connection of the power window motor and power window main switch connectors. (damaged/pulled-out pins, corrosion) Repair of replace necessary. |