DSC Off Switch Inspection
NOTE:
- The DSC OFF switch is integrated with the cluster switch.
- For the DSC OFF switch removal/installation, refer to CLUSTER SWITCH REMOVAL/INSTALLATION . (See CLUSTER SWITCH REMOVAL/INSTALLATION .)
- Remove the cluster switch. (See CLUSTER SWITCH REMOVAL/INSTALLATION .)
- Verify that the resistance between cluster switches B and C is as indicated in the table.
- If the resistance cannot be verified as indicated in the table, replace the cluster switch.
- Apply battery positive voltage to cluster switch terminal J, and connect terminal I to ground.
- Verify that the LED illuminates.
- If there is any malfunction, replace the cluster switch.