| DTC P0716:00 |
Turbine/input shaft speed sensor range/performance problem |
| DETECTION CONDITION |
- Under the following condition, the turbine/input shaft speed is 9, 000 rpm or more
for 1 s
:
- Battery voltage is 8 V or more
.
Diagnostic support note
- The check engine light illuminates if the TCM detects the above malfunction condition during the first drive cycle.
- The automatic transaxle warning light illuminates if the TCM detects the above malfunction condition during the first drive cycle.
- PENDING CODE is available.
- FREEZE FRAME DATA is available.
- DTC is stored in the TCM memory.
|
| FAIL-SAFE FUNCTION |
- Set to TCC control.
- Inhibits learning control.
- Inhibits manual mode.
- Inhibits neutral idle control.
- Inhibits AAS.
- Inhibits 5GR and 6GR.
- Inhibits shift down when the accelerator pedal is depressed.
|
| POSSIBLE CAUSE |
- Turbine/input shaft speed sensor malfunction
|
| SYSTEM WIRING DIAGRAM |
Not applicable |