| Description |
- U0010:88
- Module communication error (MS-CAN)
- U0155:00
- Communication error with instrument cluster
|
| Detection condition |
- U0010:88
- Parking sensor control module detects the CAN bus communication line (MS-CAN) malfunction 10 times continuously.
- U0155:00
- Parking sensor control module cannot receive the CAN signal from the instrument cluster for 5 s or more
.
|
| Fail-safe |
|
| Possible cause |
- Malfunction in CAN bus communication line
- Malfunction in CAN line between instrument cluster and parking sensor control module
|
| System wiring diagram |
Not applicable |