PERFORM ADDITIONAL KEY PROGRAMMING
- Connect the M-MDS (IDS) to the DLC-2. (See M-MDS (IDS) CONNECTING PROCEDURE .)
- Switch the ignition ON using key 1.
NOTE:
- Although the security indicator light starts flashing and DTC 15 is displayed after approx. 1 min, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
- After vehicle identification, select the following from the M-MDS initial screen.
- Using an IDS (laptop PC):
- "Body"
- "Security"
- "PATS (immobilizer) function"
- Then, select the "Auxiliary key addition" from the screen menu.
- Perform the security access according to the directions on the M-MDS (IDS) screen.
NOTE:
- After executing the above menu, "This operation is successful" is displayed. At this stage, the programming for the key switching the ignition ON is completed.
- After verifying that the PATS function menu is displayed again on the M-MDS (IDS) screen, switch the ignition OFF (LOCK).
- Remove key 1.
- Are there other keys to be programmed?
|
Yes |
Change the key and repeat Step 1.
NOTE:
- Additional key programming can be performed using the procedure in No. 1 Additional Key Programming Procedure (Using Two Valid Keys).
|