DSC HU/Cm Inspection: Notes
- Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION .)
- Disconnect the DSC HU/CM connector. (See DSC HU/CM REMOVAL/INSTALLATION .)
- Connect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION .)
- Attach the tester lead to the DSC HU/CM wiring harness-side connector and inspect voltage, continuity, or resistance according to the Terminal Voltage Table (Reference) on the table.