Diagnostic Procedure
AUTO CLOSURE DOES NOT OPERATE (POWER LIFTGATE (PLG) SYSTEM) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | POWER LIFTGATE (PLG) TOUCH SENSOR INSPECTION
|
Yes | Remove dirt or foreign matter, then go to the next step. |
| No | Go to the next step. | ||
| 2 | VERIFY IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN POWER LIFTGATE (PLG) CONTROL MODULE AND LIFTGATE LATCH AND LOCK ACTUATOR
|
Yes | Go to the next step. |
| No |
|
||
| 3 | VERIFY IF MALFUNCTION CAUSE IS SHORT TO GROUND IN WIRING HARNESS BETWEEN POWER LIFTGATE (PLG) CONTROL MODULE AND LIFTGATE LATCH AND LOCK ACTUATOR
|
Yes |
|
| No | Go to the next step. | ||
| 4 | DETERMINE IF MALFUNCTION CAUSE IS POWER LIFTGATE (PLG) CONTROL MODULE OR LIFGTAGE LATCH AND LOCK ACTUATOR
|
Yes | Replace the power liftgate (PLG) control module, then go to the next step. (See POWER LIFTGATE (PLG) CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Replace the liftgate latch and lock actuator, then go to the next step. (See LIFTGATE LATCH AND LOCK ACTUATOR REMOVAL/INSTALLATION .) |
||
| 5 | VERIFY IF MALFUNCTION CAUSE IS CORRECTED
|
Yes | Troubleshooting completed. (Explain the contents of the servicing to the customer.) |
| No | If the malfunction has not been resolved, repeat the inspection from Step 1. | ||