DTC P06B8-00: Internal Control Module Non-Volatile RAM Error: Notes

DTC DETECTION DESCRIPTION

DTC P06B8:00 Internal control module non-volatile RAM error
DETECTION CONDITION
  • PCM internal EEPROM malfunction.

    Diagnostic support note

  • This is a continuous monitor (other).
  • The check engine light illuminates if the PCM detects the above malfunction condition during the first drive cycle. (The check engine light may be illuminated depending on the malfunction conditions.)
  • FREEZE FRAME DATA/Snapshot data is available.
  • DTC is stored in the PCM memory.
FAIL-SAFE FUNCTION
  • Not applicable
POSSIBLE CAUSE
  • PCM connector or terminals malfunction
  • PCM internal EEPROM malfunction
SYSTEM WIRING DIAGRAM
  • Not applicable