Inspection using an oscilloscope (reference)
Roof link motor hall sensor
- Terminal connected: power retractable hardtop control module 4P (RH), 4T (LH)-Negative battery terminal
- Oscilloscope setting: 2 V/DIV (Y): 5 ms/DIV (X), DC range
- Measurement condition: When the front roof is moving.
NOTE:
- Pulse interval varies with the front roof operation speed.
Rear roof link motor hall sensor
- Terminal connected: power retractable hardtop control module 4Q (RH), 4U (LH)-Negative battery terminal
- Oscilloscope setting: 2 V/DIV (Y): 5 ms/DIV (X), DC range
- Measurement condition: When the rear roof is moving.
NOTE:
- Pulse interval varies with the rear roof operation speed.
Top lock motor hall sensor
- Terminal connected: power retractable hardtop control module 4X-Negative battery terminal
- Oscilloscope setting: 2 V/DIV (Y): 5 ms/DIV (X), DC range
- Measurement condition: When the top lock is moving.
NOTE:
- Pulse interval varies with the top lock operation speed.