DTC U3003-04: Instrument Cluster Configuration Error: Notes
DTC U3003:04 BLIND SPOT MONITORING (BSM) CONTROL MODULE DETECTION CONDITION AND POSSIBLE CAUSE
| Description |
Instrument Cluster Configuration Error |
| Detection condition |
- Instrument cluster configuration error detected.
|
| Fail-safe |
- Blind spot monitoring (BSM) system is stopped.
|
| Possible cause |
NOTE:
- To correctly write the configuration data sent from the instrument cluster to the blind spot monitoring (BSM) control module to the blind spot monitoring (BSM) control module, 30 s or more need to have elapsed since the ignition was switched ON (engine off or on).
- Instrument cluster configuration error
- Blind spot monitoring (BSM) control module malfunction
|
| System wiring diagram |
Not applicable |