DTC U3003:04 BLIND SPOT MONITORING (BSM) CONTROL MODULE DETECTION CONDITION AND POSSIBLE CAUSE

Description Instrument Cluster Configuration Error
Detection condition  
  • Instrument cluster configuration error detected.
Fail-safe  
  • Blind spot monitoring (BSM) system is stopped.
Possible cause  
NOTE:
  • To correctly write the configuration data sent from the instrument cluster to the blind spot monitoring (BSM) control module to the blind spot monitoring (BSM) control module, 30 s or more need to have elapsed since the ignition was switched ON (engine off or on).
  • Instrument cluster configuration error
  • Blind spot monitoring (BSM) control module malfunction
System wiring diagram Not applicable